STM SERIES INLINE TURBINE FLOWMETERS

HIGH ACCURACY FLOW MEASUREMENT FOR INDUSTRIAL LIQUID APPLICATIONS

The STM Series Inline Turbine Flowmeter is engineered for precise liquid flow measurement, delivering exceptional accuracy, repeatability, and long-term reliability for industrial process control, batching, and automation systems.

STM Series

RELIABLE FLOW MEASUREMENT FOR INDUSTRIAL LIQUIDS

The STM Series Inline Turbine Flowmeter is engineered for precise liquid flow measurement, delivering exceptional accuracy, repeatability, and long-term reliability for industrial process control, batching, and automation systems.

CHARACTERISTICS

  • Flow Range: Model dependent
  • Accuracy: Up to ±0.5% of reading
  • Repeatability: ±0.1%
  • Pressure: Up to 250 bar
  • Temperature: Up to 150°C
  • Body Material: SS304 / SS316
  • Output: Pulse / 4–20 mA / RS-485

KEY ADVANTAGES

  • High accuracy and repeatability
  • Low pressure drop
  • Rugged stainless steel construction
  • Wide flow range availability
  • Easy installation and maintenance
  • Suitable for automation systems
  • Compatible with PLC, DCS, SCADA, and batch controllers

SELECTION TIPS

To select the right STM flowmeter, please confirm:
  • Liquid name
  • Flow range (min/max)
  • Operating pressure & temperature
  • Required accuracy /Viscosity
  • Output signal / integration needs

STM with Pulse Output

FOR PLC, COUNTER AND TOTALIZER APPLICATIONS

STM with Pulse Output
STM with Pulse Output
STM with Pulse Output

STM with Pulse Output is suitable for applications where flow signals are required for PLC, flow totalizers, counters, batching systems, and automation panels.

STM with Pulse Output
STM with Pulse Output
STM with Pulse Output

FEATURES

  • Measuring range Screw Type: 0.2 to 70 M³/Hr
  • Measuring range Flange Type: 0.2 to 1100 M³/Hr
  • Media temperature: -30 … 150 °C
  • Maximum pressure: … 300 bar

Pulse Transmitter

  • Model – SPA – 10, SPA 100, SPA-1000
  • SPA-10 – 2 Wire, 3 Wire PNP Pulse
  • SPA-100 – Dual PNP Pulse
  • SPA – 1000 - Dual PNP Pulse
  • Enclosure – IP 66, PESO, ATEX
  • Power Supply – 24 VDC

STM with Analogue Output

CONTINUOUS FLOW MONITORING WITH STANDARD 4–20 MA OUTPUT

STM with Analogue Output
STM with Analogue Output
STM with Analogue Output

The STM with Analogue Output provides accurate and continuous flow measurement with a 4–20 mA output, enabling reliable integration with industrial control and automation systems.

STM with Analogue Output
STM with Analogue Output
STM with Analogue Output

FEATURES

  • Measuring range Screw Type: 0.2 to 70 M³/Hr
  • Measuring range Flange Type: 0.2 to 1100 M³/Hr
  • Media temperature: -30 … 60 °C
  • Maximum pressure: … 300 bar

FI Current Transmitter

  • Model – FI-8100, FI-8200
  • Output – 4-20mA, 0-10VDC
  • Serial Communication – RS 485
  • Enclosure – IP 66, PESO, ATEX
  • Power Supply – 24 VDC

Characteristics

  • 4–20 mA Analogue
  • Model Dependent (3.3 LPM to 270 m³/hr)

STM with Meter Mounted Battery-Operated Flow Indicator

SELF-POWERED LOCAL FLOW RATE & TOTAL FLOW INDICATION

STM with Meter Mounted Battery-Operated Flow Indicator
STM with Meter Mounted Battery-Operated Flow Indicator
STM with Meter Mounted Battery-Operated Flow Indicator

The STM with Meter Mounted Battery-Operated Flow Indicator offers accurate local flow rate and total flow indication with a self-powered battery display, delivering reliable performance for industrial liquid flow measurement without external power.

STM with Meter Mounted Battery-Operated Flow Indicator
STM with Meter Mounted Battery-Operated Flow Indicator
STM with Meter Mounted Battery-Operated Flow Indicator

Characteristics

  • Measuring range Screw Type: 0.2 to 70 M³/Hr
  • Measuring range Flange Type: 0.2 to 1100 M³/Hr
  • Media temperature: -30 … 60 °C
  • Maximum pressure: … 300 bar

Meter Mounted Display Unit

  • Model – UFT 9000
  • Output – 4-20mA, 0-10VDC
  • Serial Communication – RS 485
  • Enclosure – IP 66, PESO, ATEX
  • Power Supply – 24 VDC & Battery Operated

STM with Meter Mounted Flow Indicator (24 VDC Operated)

COMPACT, ACCURATE & RELIABLE FLOW MEASUREMENT WITH REAL-TIME LOCAL DIGITAL INDICATION

STM with Meter Mounted Flow Indicator (24 VDC Operated)
STM with Meter Mounted Flow Indicator (24 VDC Operated)
STM with Meter Mounted Flow Indicator (24 VDC Operated)

The STM Series Turbine Flowmeter with Meter Mounted Flow Indicator (24 VDC Operated) delivers accurate real-time flow rate and total flow indication for industrial liquid measurement. Its compact integrated design ensures easy installation, reliable performance, and long service life for process monitoring and automation.

STM with Meter Mounted Flow Indicator (24 VDC Operated)
STM with Meter Mounted Flow Indicator (24 VDC Operated)
STM with Meter Mounted Flow Indicator (24 VDC Operated)

Characteristics

  • Measuring range Screw Type: 0.2 to 70 M³/Hr
  • Measuring range Flange Type: 0.2 to 1100 M³/Hr
  • Media temperature: -30 … 60 °C
  • Maximum pressure: … 300 bar

Meter Mounted Display Unit

  • Model – UFT 8000
  • Output – 4-20mA, 0-10VDC
  • Serial Communication – RS 485
  • Enclosure – IP 66, PESO, ATEX
  • Power Supply – 24 VDC

STM with Panel Mounted Flow Indicator 230VAC Operated

ACCURATE FLOW MEASUREMENT WITH REMOTE PANEL-MOUNTED DIGITAL INDICATION

STM with Panel Mounted Flow Indicator 230VAC Operated
STM with Panel Mounted Flow Indicator 230VAC Operated
STM with Panel Mounted Flow Indicator 230VAC Operated

The STM Series Turbine Flowmeter with Panel Mounted Flow Indicator (230 VAC Operated) provides accurate real-time flow rate and total flow indication for industrial liquid measurement. Its remote panel-mounted design ensures easy operation, reliable performance, and seamless integration into process control and automation systems.

STM with Panel Mounted Flow Indicator 230VAC Operated
STM with Panel Mounted Flow Indicator 230VAC Operated
STM with Panel Mounted Flow Indicator 230VAC Operated

Characteristics

  • Measuring range Screw Type: 0.2 to 70 M³/Hr
  • Measuring range Flange Type: 0.2 to 1100 M³/Hr
  • Media temperature: -30 … 150 °C
  • Maximum pressure: … 300 bar

Panel Mounted Display Unit

  • Model – FRT 7000
  • Output – 4-20mA, 0-10VDC
  • Serial Communication – RS 232
  • Enclosure – IP 66, PESO, ATEX
  • Power Supply – 230 VAC or 24 VDC

STM with Wall Mounted Flow Indicator 230VAC Operated (Batching Systems)

ACCURATE PRESET BATCHING, FILLING & DISPENSING SOLUTION FOR INDUSTRIAL LIQUIDS

STM with Wall Mounted Flow Indicator 230VAC Operated (Batching Systems)
STM with Wall Mounted Flow Indicator 230VAC Operated (Batching Systems)
STM with Wall Mounted Flow Indicator 230VAC Operated (Batching Systems)

The STM Series Turbine Flowmeter Based Wall Mounted Preset Batching System (230 VAC Operated) delivers precise automatic batching, filling, and dispensing with real-time flow rate and total flow indication. Designed for accurate volume control, repeatable batch operations, and seamless integration into industrial process automation.

STM with Wall Mounted Flow Indicator 230VAC Operated (Batching Systems)
STM with Wall Mounted Flow Indicator 230VAC Operated (Batching Systems)
STM with Wall Mounted Flow Indicator 230VAC Operated (Batching Systems)

Characteristics

  • Measuring range Screw Type: 0.2 to 70 M³/Hr
  • Measuring range Flange Type: 0.2 to 1100 M³/Hr
  • Media temperature: -30 … 150 °C
  • Maximum pressure: … 300 bar

Wall Mounted Display Unit

  • Model – UFT 8000-P Batch Controller
  • Output – 4-20mA, 0-10VDC
  • Serial Communication – RS 485
  • Enclosure – IP 66, PESO, ATEX
  • Power Supply – 24 VDC or 230 VAC

Datasheet Download

Download the product datasheet for technical specifications.

STM SERIES INLINE TURBINE FLOWMETERS Datasheet

Download the datasheet for this product.

Industry-wise Applications

1. Oil & Gas Industry
  • Measurement of crude oil and refined products
  • Fuel dispensing (diesel, gasoline, jet fuel)
  • Pipeline and terminal flow monitoring
2. Chemical & Petrochemical
  • Measurement of solvents, alcohols, & light chemicals
  • Monitoring of process fluids in batch/continuous plants
  • Custody transfer of refined products
3. Food & Beverage Industry
  • Juices, milk, beer, & syrups (low viscosity)
  • Process water monitoring
  • Bottling and filling lines
4. Power Generation
  • Boiler feedwater monitoring
  • Cooling water circulation measurement
  • Fuel oil measurement for generators
5. Pharmaceutical Industry
  • Purified water (WFI – Water for Injection)
  • Solvent and alcohol flow monitoring
  • Process liquid batching and blending
6. Aerospace & Automotive
  • Aviation fuel flow measurement
  • Hydraulic oil flow testing
  • Engine test benches for performance
7. HVAC & Utilities
  • Chilled water measurement
  • Heating system water flow monitoring
  • Industrial utility fuel/water distribution
8. Water & Wastewater
  • Distribution and consumption monitoring
  • Cooling water measurement in plants
  • Potable water measurement

Common Construction Options

Common Construction Options

  • Body materials: SS304, SS316
  • Connections: BSP/NPT threaded, flanged, tri-clamp
  • Rotor – ANC 21 , Duplex SS
  • Bush – TC & PTFE , PEEK
  • Shaft - TC & Duplex SS
  • Pick Off Sensor – Magnetic and Hall Sensor
  • Outputs: Pulse, 4–20 mA, Modbus, Display-integrated or Remote
  • Sizes: From ¼” to 8” (and higher for special designs)

Selection Tips

When choosing an inline turbine flowmeter, consider the following process data:
  • Flow rate (Min / Max)
  • Pressure (Min / Max)
  • Temperature (Min / Max)
  • Liquid density & viscosity
Scroll to Top